Ncma tek national concrete masonry association an information series from the national authority on concrete masonry technology concrete masonry gravity retaining wallstek 15 6 structural 1995 keywords.
Mass concrete retaining wall design.
Sketches of the retaining wall forces should be considered to properly distinguish the different forces acting on our retaining wall as tackled in the previous article retaining wall.
Counterfort retaining walls are more economical than cantilever walls for heights above 25 ft.
Design tanδ tan 20º or 0 75xdesign tanφ 0 364 or 0 503 design tanδ 0 364 from table design φ 33 8º design δ 20º ka 0 242 10kn m surcharge on retained soil behind wall.
Building codes and retaining walls 5.
Allowable stress design lateral loads plain concrete masonry retaining wall unreinforced concrete masonry designed to resist sliding by using reinforcement.
Both proprietary block and crib retaining walls must be built on an in situ concrete foundation or on a compacted base course.
Try 1400mm thick wall.
The stem may have constant thickness along the length or may be tapered based on economic and construction criteria.
Two equations are developed.
The no fines mix aids resistance to shearing by increasing friction between units and the permeability helps to relieve hydrostatic pressure build up behind the wall.
Reinforced concrete cantilever retaining wall analysis and design aci 318 14 reinforced concrete cantilever retaining walls consist of a relatively thin stem and a base slab.
Gravity poured concrete retaining walls.
Another type of gravity wall is the crib retaining wall which comprises a system of interlocking header and stretcher blocks to retain the granular fill that provides the mass to the wall.
Ce 437 537 spring 2011 retaining wall design example 1 8 design a reinforced concrete retaining wall for the following conditions.
They are generally economical up to 10 feet in height for cast concrete structures.
Retaining wall design 10 editionth a design guide for earth retaining structures contents at a glance.
Because of their large mass.
F c 3000 psi fy 60 ksi natural soil development of structural design equations.
The blocks are interlocked by a key joint precast into the blocks.
Design procedure overview 3.
Earthquake seismic design 7.
Based on our example in figure a 1 we have the forces due to soil pressure due to water and surcharge load to consider.
Construction is mortar less and an experienced crew can place up to 80m2 of wall per day.
Forces on retaining walls 6.
P w due to active pressure surcharge wall self weight 1 wall self weight 2 weight of soil wall friction ia m 0 5 x 0 242 x 18 x 2.
The base is divided into two parts the heel and toe.
Soil bearing and stability 8.
The rocla massbloc instant wall system is comprised of large permeable precast concrete blocks for various retaining applications for walls typically 2 8 metres in height.